E1 218
Worcester Bosch Ignition Lockout / No Flame Signal

Boiler shows E1 218 and will not ignite, often after power interruptions.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty ignition transformer on PCB, Damaged ignition lead, Incorrect electrode position, Gas valve not energised

How to Fix / Troubleshooting

Safety first: Turn off power and gas before removing covers. Gas work must be done by a Gas Safe engineer.

  • Single reset attempt: Press the reset button once. If the boiler still fails to ignite and E1 218 returns, further diagnosis is needed.
  • Visual inspection: Check the ignition lead for cracks, burns, or loose connections at the electrode and PCB.
  • Engineer tasks: A professional should verify spark generation at the electrode, test the ignition circuit on the PCB, and confirm that the gas valve is being energised during ignition. Replace the ignition lead or PCB if defective.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Ignition Lead
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements