Worcester Bosch
Partial Circulation / System Balancing Issue
Radiators upstairs get hot but downstairs remain cold.
Advertisements
Possible Causes
Sludge build-up in lower circuits, Incorrectly balanced radiators, Pump not powerful enough or set too low, Air trapped in downstairs pipework
How to Fix / Troubleshooting
Safety first: Allow radiators to cool before adjusting valves.
- Bleed downstairs radiators: Remove any trapped air and top up system pressure afterwards.
- Balance radiators: Slightly close lockshield valves on radiators that heat quickly (usually upstairs) to force more flow to cooler radiators.
- Engineer assistance: If balancing does not help, an engineer should check for sludge, clean filters, and possibly powerflush the system.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
System Pipework (no single part)
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements