Worcester DHW Priority / Plate Heat Exchanger Flow Fault

Radiators get hot but domestic hot water is lukewarm or cold on a Worcester combi boiler.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked plate heat exchanger, diverter valve not fully moving to DHW position, scaled DHW side, faulty DHW flow sensor

How to Fix / Troubleshooting

Safety first: Water may be hot; take care when testing taps.

Homeowner checks:

  • Run a single hot tap fully open and see if the boiler fires and stays on.
  • Ensure cold inlet and hot outlet isolation valves under the boiler are fully open.

Engineer actions:

  • Check DHW flow rate and verify the DHW flow sensor is detecting demand.
  • Inspect and clean or replace the plate heat exchanger if restricted by scale or sludge.
  • Test the diverter valve motor and mechanism; replace or service if not fully diverting to DHW.

Restoring DHW performance often involves descaling or replacing the plate heat exchanger on Worcester combis.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Plate Heat Exchanger
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements