B&D Insufficient Close Travel or Door Warping

Opener operates but door does not fully close, leaving a small gap, and weather seal does not contact the floor.

Advertisements

Possible Causes

Close limit set short, compressed or new thicker bottom seal, warped door bottom rail, high spot in floor

How to Fix / Troubleshooting

Safety first: Ensure safety reversal still functions after adjustments.

  • Step 1 – Inspect bottom seal and floor: Identify whether the gap is due to a high spot in the floor or a warped door.
  • Step 2 – Adjust close limit slightly: Increase close travel just enough so the seal compresses against the floor without excessive force.
  • Step 3 – Test reversal: Place a 40 mm object under the door and confirm it reverses on contact.
  • Step 4 – Consider seal or floor repair: If the floor is uneven, consider installing a threshold or planing high spots. Replace a deformed bottom seal if necessary.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Bottom Weather Seal
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements