E01
BFT Mains Power Supply or Transformer Fault

BFT garage door opener will not start; control unit display shows E01 immediately after power-up.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blown mains fuse on BFT control board, Faulty internal transformer on BFT control unit, Loose or burned power terminal connections, Incorrect supply voltage selection on control board

How to Fix / Troubleshooting

Safety first: Disconnect mains power at the breaker before opening the operator housing. High voltage is present inside BFT control units (e.g., ALENA, MERAK, RIGEL boards).

  • Check incoming power: Verify that the dedicated circuit breaker is ON and supplying the correct voltage (typically 230 V AC in EU or 120 V AC in NA, depending on model). Use a multimeter at the line input terminals (L/N) of the BFT control board.
  • Inspect the mains fuse: Locate the glass or cartridge fuse on the BFT control board (often labeled F1 or T2A/T3.15A). Remove and test for continuity. Replace only with the same rating and slow/fast-blow type as specified in the BFT manual.
  • Check transformer connections: On models with a separate transformer, ensure primary and secondary wires are firmly seated in the terminals and show no signs of overheating or burning.
  • Measure low-voltage output: With power restored (and covers in place where required), carefully measure the transformer secondary (often 24 V AC) at the control board. If no low-voltage output is present but mains is OK, the transformer is likely faulty.
  • Inspect for board damage: Look for burnt tracks, bulged capacitors, or darkened areas around the power supply section. If present, the entire control board should be replaced rather than repaired in the field.

If you are not comfortable working around mains voltage, contact a qualified BFT technician.