CAME Incorrect Travel Limit Learning or Excessive Sensitivity

Garage door moves a short distance then stops, requiring multiple presses to fully open or close

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incomplete limit programming on CAME control unit, Force/sensitivity trimmer set too low, Door binding in tracks, Encoder miscounting travel

How to Fix / Troubleshooting

Safety first: Keep clear of the moving door during tests.

Steps:

  • Check door mechanics: Disconnect the operator using the manual release and move the door by hand. Correct any binding, bent tracks, or seized rollers.
  • Adjust force: On the CAME board, slightly increase the force/sensitivity setting within safe limits.
  • Re‑learn limits: Follow the CAME procedure to erase and reprogram the open and close limits, allowing the door to travel fully in both directions.
  • Inspect encoder/limits: Ensure the encoder or limit switches are secure and not slipping.

After reprogramming, run several full cycles to confirm consistent travel.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

CAME control unit (limit memory) / encoder