2-4
Chamberlain Obstruction or Hard Spot in Door Travel

Garage door stops and reverses at the same point on every close; opener lights flash 2 times, pause, then 4 times (logic board LED code 2-4).

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Bent track at a specific location, Damaged roller, Loose hinge or bracket, Door panel damage causing binding

How to Fix / Troubleshooting

Safety first: Disconnect power and pull the emergency release before manually moving the door. Do not place fingers between door sections.

Steps to fix:

  • Move door by hand: With the opener disengaged, slowly move the door through its full travel. Feel for any tight spots or binding at the same location where the opener reverses.
  • Inspect tracks: Look for dents, bends, or misalignment in the vertical and horizontal tracks at that location. Use a rubber mallet and a block of wood to gently straighten minor bends. Replace severely damaged sections.
  • Check rollers and hinges: Spin each roller by hand. Replace any that are seized, flat-spotted, or wobbling. Tighten loose hinge screws and bracket bolts.
  • Verify clearance: Ensure no hardware, wiring, or storage items are contacting the door or track at the problem point.
  • Lubricate: Apply lubricant to rollers and hinges, then move the door several times to distribute.
  • Re-engage opener and test: Reconnect the trolley, restore power, and run the door. If the obstruction is removed, the 2-4 code should clear.