5-2
Chamberlain Battery Backup Failure

Battery backup not functioning during power outage; logic board LED flashes 5 times, pause, then 2 times (5-2).

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open battery circuit, Blown internal fuse, Failed charging circuit on logic board, Incorrect battery type installed

How to Fix / Troubleshooting

Safety first: Disconnect AC power before testing the battery circuit. Avoid shorting the battery terminals.

Steps to fix:

  • Verify correct battery: Ensure the installed battery matches Chamberlain’s specified voltage and capacity.
  • Test battery voltage: Use a multimeter to measure across the battery terminals. A healthy 12V battery should read around 12.5–13.5V when charged.
  • Inspect internal fuse (if accessible): Some models include a fuse in the battery circuit. Replace if blown with the same rating.
  • Replace battery: If voltage is low and does not recover after charging, replace the battery.
  • Replace logic board: If a known-good battery does not operate the opener during an outage and the 5-2 code persists, the charging/backup circuit on the logic board is likely defective.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Battery Backup and Charging Circuit (Logic Board)