5-3
Chamberlain Battery Overvoltage or Reverse Polarity

Constant beeping from opener; battery indicator shows fault; logic board LED flashes 5 times, pause, then 3 times (5-3).

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Battery connected backwards, Wrong battery voltage, Charging circuit fault, Loose or shorted battery leads

How to Fix / Troubleshooting

Safety first: Immediately disconnect AC power and the battery if you suspect reverse polarity or overheating. Batteries can vent or explode if miswired.

Steps to fix:

  • Check polarity: Confirm the red lead is on the positive (+) terminal and the black lead is on the negative (−) terminal of the battery.
  • Verify battery type: Use only the Chamberlain-specified 12V battery. Remove any incorrect battery.
  • Inspect leads: Look for pinched or shorted battery wires inside the housing. Repair or replace as needed.
  • Install new battery: If the existing battery has been connected incorrectly, replace it with a new one.
  • Test operation: Reconnect power and confirm the beeping and 5-3 code are cleared. If not, the charging circuit on the logic board may be damaged and require replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Battery Backup and Harness
Check Price on Amazon