5-3
Chamberlain
Battery Overvoltage or Reverse Polarity
Constant beeping from opener; battery indicator shows fault; logic board LED flashes 5 times, pause, then 3 times (5-3).
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Battery connected backwards, Wrong battery voltage, Charging circuit fault, Loose or shorted battery leads
How to Fix / Troubleshooting
Safety first: Immediately disconnect AC power and the battery if you suspect reverse polarity or overheating. Batteries can vent or explode if miswired.
Steps to fix:
- Check polarity: Confirm the red lead is on the positive (+) terminal and the black lead is on the negative (−) terminal of the battery.
- Verify battery type: Use only the Chamberlain-specified 12V battery. Remove any incorrect battery.
- Inspect leads: Look for pinched or shorted battery wires inside the housing. Repair or replace as needed.
- Install new battery: If the existing battery has been connected incorrectly, replace it with a new one.
- Test operation: Reconnect power and confirm the beeping and 5-3 code are cleared. If not, the charging circuit on the logic board may be damaged and require replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Battery Backup and Harness
Check Price on Amazon
We may earn a commission from links on this page.