6-2
Chamberlain
Down Limit or Force Conflict
Door opens but will not close fully; logic board LED flashes 6 times, pause, then 2 times (6-2).
Advertisements
Possible Causes
Down limit set too far, Excessive down force, Door hitting obstruction, Travel calibration error
How to Fix / Troubleshooting
Safety first: Do not increase force to overcome a physical obstruction. Correct mechanical issues first.
Steps to fix:
- Inspect floor area: Remove any objects or debris from the door threshold.
- Adjust down travel: Reduce the DOWN travel slightly so the door stops just at the floor without pushing hard.
- Adjust down force: Reduce the DOWN force setting to the minimum that reliably closes the door.
- Re-run travel setup: Perform a full travel reprogramming per the manual to synchronize limits and force.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Travel / Force Adjustment Assembly
Check Price on Amazon