Garador Over‑Travel / Incorrect Close Limit Setting

Door hits the floor hard when closing or bounces back slightly before stopping.

Advertisements

Possible Causes

Close limit set too far, Door seal recently replaced with thicker profile, Floor level changed, Limit cam slipped on shaft

How to Fix / Troubleshooting

Safety first: Avoid standing under the door while adjusting limits.

  • Inspect bottom seal: If a new Garador bottom seal has been fitted, note its increased thickness; the close limit must be adjusted accordingly.
  • Adjust close limit: Use the limit adjustment buttons or dials on the Garador operator to reduce the closing travel slightly so the door just compresses the seal without excessive force.
  • Check for bounce: Run several close cycles and watch for bounce or re‑opening. Fine‑tune the limit until the door stops smoothly.
  • Verify safety reversal: Perform a contact reversal test with a solid object under the door to ensure safety functions still operate correctly.
Advertisements

Repair Difficulty

Easy 2/5