Garador
Safety Override Closing Mode
Door opens normally but will not close unless the wall button is held down continuously.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Photocell or safety edge fault, Safety input not satisfied, Control configured in hold‑to‑run mode, Faulty safety test circuit
How to Fix / Troubleshooting
Safety first: This behaviour indicates a safety device problem. Do not bypass safety devices for everyday use.
- Check photocells: Verify alignment, wiring, and LED status of Garador photocells. Repair or replace as needed.
- Inspect safety edge: Test the bottom edge device and its wiring or wireless link. Replace if non‑functional.
- Check configuration: In the control menu, ensure the operator is set to automatic mode, not hold‑to‑run, unless required by local regulations.
- Reset and test: After correcting safety devices, power cycle the operator and test closing from remote and wall button.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Garador Photocell Safety Beam Kit / Bottom Safety Edge
Check Price on Amazon