Incorrect Open Limit Setting / Travel Loss
Door will not open fully; stops 10–30 cm short of the usual open position.
Advertisements
Possible Causes
Open limit drifted or lost after power cut, Slipping limit cam or encoder, Obstruction at header or track, Door arm hitting bracket
How to Fix / Troubleshooting
Safety first: Disconnect power before adjusting mechanical stops or brackets.
- Inspect for obstructions: Check the top of the door, header, and track for any new brackets, insulation, or objects that might stop the door early.
- Check door arm: Ensure the Garador door arm is not contacting the operator head or ceiling before full open.
- Reprogram open limit: Follow the Garador manual to adjust or relearn the open limit position. Move the door to the desired fully open point and store the setting.
- Verify multiple cycles: Run the door several times to confirm it consistently reaches the correct open height.