E13
Garador Accessory Bus / Add‑On Module Fault

E13 displayed, operator will not run and may emit a continuous beep; often after accessories are added.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Shorted accessory module (e.g., external receiver, timer), Incorrect wiring to accessory terminals, Overloaded 24 V accessory output, Faulty loop detector or keypad

How to Fix / Troubleshooting

Safety first: Disconnect power before removing or adding accessories.

  • Remove all accessories: Disconnect all devices from the accessory terminals (keypads, timers, external receivers, loop detectors, etc.).
  • Power test: Restore power with no accessories connected. If E13 clears, one of the accessories or its wiring is faulty.
  • Reconnect one by one: Connect each accessory in turn, powering down between changes if required. When E13 reappears, the last connected device or cable is the culprit.
  • Check accessory ratings: Ensure the total current draw on the 24 V output does not exceed Garador's specified limit. Remove or power heavy accessories from a separate supply.
  • Replace faulty module: Replace any accessory that causes E13 when connected, or correct its wiring according to the Garador wiring diagram.
Advertisements

Repair Difficulty

Medium 3/5