Garador Stuck Light Relay or Logic Fault

Operator courtesy light does not turn off after the usual timeout.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Relay contacts welded closed, Incorrect wiring of external light, Firmware bug, Shorted light output

How to Fix / Troubleshooting

Safety first: Turn off power before inspecting wiring.

  • Check external light wiring: If an external light is connected, verify it is wired to the correct Garador terminals and not back‑feeding power.
  • Power cycle: Disconnect power for 1–2 minutes and restore. Observe if the light now times out correctly.
  • Inspect board: Look for a stuck or burnt relay on the control board. If found, replace the board.
  • Temporary workaround: Remove the bulb to prevent continuous operation until the board can be replaced.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Garador Control Board (Light Relay)
Check Price on Amazon