Gliderol
Travel Limit Misadjustment
Gliderol garage door opener runs but door only moves a short distance then stops without reversing.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Incorrectly set open/close limit cams, Slipping limit shaft, Misprogrammed electronic limits, Loose limit switch bracket
How to Fix / Troubleshooting
Safety first: Disconnect power before adjusting mechanical limit cams.
Steps to correct short travel:
- 1. Identify limit type: Determine if your Gliderol opener uses mechanical cams or electronic programming.
- 2. Adjust mechanical cams: For cam types, rotate the open and close cams on the shaft so they actuate the switches at the correct door positions. Tighten set screws.
- 3. Reprogram electronic limits: For electronic models, enter limit setup mode and drive the door fully open and closed, storing each position as per the manual.
- 4. Tighten brackets: Ensure the limit switch bracket is firmly mounted and not flexing.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Gliderol Limit Switch Assembly
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements