Gliderol
Intermittent Safety Beam Connection
Gliderol opener’s safety beams work intermittently; sometimes the door closes, sometimes it reverses with no obstruction.
Advertisements
Possible Causes
Loose beam wiring at terminals, Damaged cable from impact or rodents, Poor beam alignment due to loose brackets, Sunlight interference on receiver
How to Fix / Troubleshooting
Safety first: Do not bypass beams; fix the underlying issue.
Steps to stabilise safety beams:
- 1. Tighten terminals: Re‑terminate the beam wires at both the beams and the Gliderol control board.
- 2. Secure brackets: Tighten beam mounting screws so they cannot move when bumped.
- 3. Shield from sun: If direct sunlight hits the receiver, fit a small shade or reposition slightly.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Gliderol Safety Beam Kit
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements