11
Guardian
Over-Sensitive Down Force or Mis-leveled Floor Detection
Guardian opener LED shows code “11”, door reverses immediately upon touching the floor.
Advertisements
Possible Causes
Down force set too low, Uneven garage floor, Loose door arm or bracket, Travel limits slightly mis-set
How to Fix / Troubleshooting
Safety first: Keep clear of the moving door while adjusting force and limits. Do not over-increase force; it must still reverse on obstruction.
- Check door hardware: Inspect the door arm connection to the top section and the header bracket on the wall. Tighten any loose bolts.
- Adjust down travel: Reduce the down travel slightly so the door does not push hard into a high spot on the floor.
- Increase down force slightly: Using the Guardian force adjustment, increase the down force one small step at a time, testing after each adjustment. The door should close firmly but still reverse when it hits a 2x4 laid flat on the floor.
- Shim the floor if needed: If the floor is significantly uneven, consider adding a flexible bottom seal or threshold to provide a more even contact surface.