E20
Henderson Motor Direction or Phase Error

Display shows E20; door moves erratically or in the wrong direction.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect motor wiring on control board, Reversed limit wiring, Faulty direction relay on PCB, Misconfigured direction setting

How to Fix / Troubleshooting

Safety first: Disconnect power before changing any wiring. Unexpected door movement can cause injury.

Steps:

  • Verify wiring: Compare motor and limit switch wiring to the Henderson schematic. Correct any swapped wires, especially up/down limit leads.
  • Direction setting: Some models allow reversing motor direction via a jumper or menu setting. Ensure it matches the installation orientation.
  • Test operation: After corrections, run the door through a full open and close cycle while observing direction and stopping points.
  • If E20 persists: The direction control relay or triac on the Henderson control PCB may be defective. Replace the board.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Henderson Control PCB
Check Price on Amazon

We may earn a commission from links on this page.