Henderson Over‑Sensitive Down Force or Misadjusted Travel Limit

Garage door reverses immediately after hitting the floor.

Advertisements

Possible Causes

Down force set too low, Close limit set too far, Door binding at bottom seal, Warped door sections

How to Fix / Troubleshooting

Safety first: Keep people and objects clear of the door while adjusting.

Steps:

  • Inspect bottom seal and floor: Look for raised thresholds, objects, or uneven concrete causing early resistance.
  • Adjust close limit: Use the Henderson limit adjustment (dials or programming) to slightly reduce the close travel so the door stops as soon as it contacts the floor.
  • Increase down force slightly: Turn the down force control up in small increments, testing after each change. Do not exceed manufacturer recommendations.
  • Test safety reversal: Place a 50 mm (2 in) block under the door and close. The door must reverse upon contact.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Henderson Door Bottom Seal
Check Price on Amazon

We may earn a commission from links on this page.