Hormann
Misaligned Photocells Causing False Trigger at End of Travel
Door closes then immediately reopens a short distance
Advertisements
Possible Causes
Photocell beam partially blocked by door hardware, Photocell brackets twisted, Sunlight interference on receiver
How to Fix / Troubleshooting
Safety first: Keep people and vehicles clear while testing.
Step-by-step:
- Observe LEDs: Watch the photocell indicator LEDs while the door closes. If they flicker or go out just before full close, alignment is marginal.
- Reposition brackets: Adjust the photocell mounting so that the beam is not grazed by the door, hinges, or bottom seal when closed.
- Shield from sunlight: If direct sun hits the receiver, fit a small shade or hood (without blocking the beam) or slightly angle the sensors to reduce glare.
- Retest: Run several close cycles and confirm the door stays closed.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Hormann Photocell Set and Mounting Brackets
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements