Hormann
Threshold Obstruction or Floor Irregularity
Door reverses when almost closed, bottom seal does not fully contact floor
Advertisements
Possible Causes
Raised floor area, Debris at threshold, Bottom seal too stiff or damaged, Close force set too low
How to Fix / Troubleshooting
Safety first: Keep feet and objects away from the closing edge while testing.
Step-by-step:
- Clean threshold: Remove stones, ice, or debris from the floor where the door lands.
- Inspect bottom seal: Check the Hormann bottom rubber for hardening, tears, or deformation. Replace if damaged.
- Check floor level: If the floor is uneven, consider fitting a tapered bottom seal or threshold ramp to provide a uniform contact surface.
- Adjust close force slightly: Increase the closing force parameter within safe limits so the operator can compress the seal without reversing prematurely.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Bottom Seal / Weatherstrip
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements