9
Hormann
Photocell or Safety Device Bypassed / Faulty Logic
Display shows “9”, door opens but will not close via remote
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Incorrect bridging of safety inputs, Misconfigured operating mode, Defective safety input on control board, Faulty wall control wiring
How to Fix / Troubleshooting
Safety first: Ensure the door area is clear. Disconnect power before changing wiring.
Step-by-step:
- Review wiring: At the control board, verify that safety inputs (photocell, safety edge, stop) are wired exactly as per the Hormann diagram. Remove any unauthorized jumpers or incorrect bridges.
- Check wall station: If a Hormann wall console is installed, disconnect it temporarily and test operation with only the remote. A shorted wall button or cable can block closing.
- Operating mode: Some Hormann controls allow “open‑only” or partial modes. Enter the programming menu and confirm that standard automatic mode is selected.
- Test safety devices: Confirm that photocells and safety edges are functioning and not permanently triggered.
- If error persists: The logic input section of the control board may be defective and require replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Hormann Control Board (Logic Inputs) or Wall Control
Check Price on Amazon
We may earn a commission from links on this page.