9
Hormann Photocell or Safety Device Bypassed / Faulty Logic

Display shows “9”, door opens but will not close via remote

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect bridging of safety inputs, Misconfigured operating mode, Defective safety input on control board, Faulty wall control wiring

How to Fix / Troubleshooting

Safety first: Ensure the door area is clear. Disconnect power before changing wiring.

Step-by-step:

  • Review wiring: At the control board, verify that safety inputs (photocell, safety edge, stop) are wired exactly as per the Hormann diagram. Remove any unauthorized jumpers or incorrect bridges.
  • Check wall station: If a Hormann wall console is installed, disconnect it temporarily and test operation with only the remote. A shorted wall button or cable can block closing.
  • Operating mode: Some Hormann controls allow “open‑only” or partial modes. Enter the programming menu and confirm that standard automatic mode is selected.
  • Test safety devices: Confirm that photocells and safety edges are functioning and not permanently triggered.
  • If error persists: The logic input section of the control board may be defective and require replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Hormann Control Board (Logic Inputs) or Wall Control
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements