LiftMaster Down Force Too Low or Door Binding

Garage door reverses before reaching the floor; no visible obstruction.

Advertisements

Possible Causes

Down force setting too low, stiff door rollers, misaligned tracks, warped door sections

How to Fix / Troubleshooting

Safety: Do not over-increase force; always verify safety reversal.

  • Inspect door movement: Disconnect opener and move door by hand. Correct any binding or stiffness.
  • Lubricate hardware: Lubricate rollers, hinges, and bearings.
  • Increase down force slightly: Turn the down force adjustment screw or change electronic setting in small increments, testing after each change.
  • Test safety: Perform the 2x4 reversal test to ensure the door still reverses on obstruction.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Force Adjustment System
Check Price on Amazon