LiftMaster
Down Force Too Low or Door Binding
Garage door reverses before reaching the floor; no visible obstruction.
Advertisements
Possible Causes
Down force setting too low, stiff door rollers, misaligned tracks, warped door sections
How to Fix / Troubleshooting
Safety: Do not over-increase force; always verify safety reversal.
- Inspect door movement: Disconnect opener and move door by hand. Correct any binding or stiffness.
- Lubricate hardware: Lubricate rollers, hinges, and bearings.
- Increase down force slightly: Turn the down force adjustment screw or change electronic setting in small increments, testing after each change.
- Test safety: Perform the 2x4 reversal test to ensure the door still reverses on obstruction.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Force Adjustment System
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements