Up Travel Limit Misadjusted or Door Binding at Top
Garage door stops just short of fully open; must hold wall button or adjust each time.
Advertisements
Possible Causes
Up limit set too low, door hitting stop bolt or opener arm angle limit, weak springs, track misalignment near header
How to Fix / Troubleshooting
Safety: Avoid forcing the door beyond its designed travel.
- Inspect top travel: Watch the door as it opens. Ensure it is not hitting the stop bolt, opener arm, or header.
- Adjust up travel: Increase the up travel slightly using the adjustment screw or electronic setting until the door opens fully without hitting stops.
- Check hardware: Verify top fixtures and tracks are not bent or obstructed.
- Test balance: If the door drifts down from fully open when disconnected, have springs adjusted.