Linear
Close Command Inhibited
Door opens normally but will not close at all from any control.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Photo eyes not functioning, Close limit already considered reached, Faulty close relay on board, Miswired external close inhibit input
How to Fix / Troubleshooting
Safety first: Keep the opening clear while testing. Do not bypass safety devices permanently.
- 1. Verify sensors: Confirm both photo eye LEDs are lit and aligned. Repair as needed.
- 2. Reset opener: Disconnect power for 30 seconds, then restore. Try a close command again.
- 3. Check external inputs: If external controls (loops, key switches) are connected, temporarily disconnect them to rule out a stuck close inhibit signal.
- 4. Reprogram limits: If the opener thinks it is already at the close limit, re-learn the travel limits per the Linear manual.
- 5. Replace control board: If none of the above restores closing, the close control circuitry on the board may be defective.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Photo Eye Safety Sensors / Main Control Board