Mighty Mule
Incorrectly Set Travel Limits After Installation
Opener runs but door only moves a few inches and then reverses direction.
Advertisements
Possible Causes
Initial limits not programmed correctly, Limit nuts positioned too close together, Encoder calibration incomplete, Installer stopped door mid-program
How to Fix / Troubleshooting
Safety first: Ensure the door path is clear before reprogramming travel.
- Reset programming: Follow the Mighty Mule installation manual to clear existing travel limits.
- Run full cycle: Put the opener into learn mode and allow it to run the door fully open and fully closed without interruption.
- Verify stops: Confirm the door stops at the correct fully open and fully closed positions. Adjust fine travel if your model allows.
- Re-test: Operate the door several times to ensure consistent travel without reversal.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Mighty Mule Limit Switch Assembly
Check Price on Amazon
We may earn a commission from links on this page.