DISPLAY CODE E1
Motorlift Input Power or Line Voltage Error

Motorlift opener with digital display shows E1 and will not operate the door.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect supply voltage, Loose power cord connection, Tripped circuit breaker, Internal power supply fault on logic board

How to Fix / Troubleshooting

Safety first: Turn off power at the breaker before inspecting wiring. Only qualified persons should open junction boxes.

Steps to diagnose:

  • Verify outlet power: Plug a lamp or tester into the opener outlet. If no power, reset the breaker or replace a blown fuse.
  • Check power cord: Inspect the Motorlift power cord for cuts or damage. Ensure it is fully inserted into the outlet.
  • Inspect internal connections: If hardwired, remove the opener cover and check that the line and neutral wires are secure at the terminal block.
  • Power cycle: Turn power off for 1–2 minutes, then restore. If E1 clears, monitor for recurrence.
  • Replace logic board: If correct voltage is present and E1 persists, the internal power supply on the logic board is likely faulty and the board should be replaced.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Motorlift Logic/Control Board
Check Price on Amazon