Nice
Over‑Sensitive Obstacle Detection / Force Setting Issue
Door closes then immediately reopens about 10–20 cm, without any error code on the Nice unit.
Advertisements
Possible Causes
Force/torque setting too low, Stiff door hinges or rollers, New weather seal increasing resistance, Incorrect door type setting in Nice controller
How to Fix / Troubleshooting
Safety first: Do not increase force beyond manufacturer recommendations; fix mechanical issues first.
- Check door movement by hand: Release the opener and move the door manually. It should move smoothly with moderate effort. Lubricate hinges and rollers and correct any binding.
- Inspect bottom seal: If a new, thicker seal was installed, the door may require a small limit adjustment so it does not compress excessively.
- Adjust force slightly: Increase the close force parameter or trimmer on the Nice board in small increments, testing after each change.
- Verify door type setting: Ensure the controller is programmed for the correct door type (sectional, up‑and‑over, etc.), as this affects force profiles.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Nice control board (force adjustment)
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements