E11
Nice Open‑Only Mode or Close Command Inhibited by Safety Input

E11 is displayed and the door opens but will not close using remote or wall button.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Active photocell input during close, Safety edge reporting fault only in closing direction, Misconfigured logic (e.g., condominium mode) on Nice board, Stuck open limit switch

How to Fix / Troubleshooting

Safety first: Keep people and vehicles clear of the door while testing.

  • Check safety devices during close: Command the door to close and watch the photocell LEDs and safety edge. If the beam is blocked or the edge is compressed, the board will inhibit closing.
  • Verify logic mode: In the Nice programming menu, confirm the operating logic (step‑by‑step, automatic closing, condominium, etc.) is appropriate for a residential door. Some logics restrict closing from certain commands.
  • Inspect close limit switch: If the board thinks the door is already closed, it may ignore close commands. Check the close limit switch or encoder reference and re‑set limits if necessary.
  • Test with photocells bypassed (temporarily for diagnosis only): If allowed by local regulations, temporarily bridge the photocell terminals at the board to see if the door will close. If it does, the photocells or their wiring are at fault. Restore proper safety devices immediately after testing.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Nice photocell circuit or limit switch
Check Price on Amazon

We may earn a commission from links on this page.