E11
Nice
Open‑Only Mode or Close Command Inhibited by Safety Input
E11 is displayed and the door opens but will not close using remote or wall button.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Active photocell input during close, Safety edge reporting fault only in closing direction, Misconfigured logic (e.g., condominium mode) on Nice board, Stuck open limit switch
How to Fix / Troubleshooting
Safety first: Keep people and vehicles clear of the door while testing.
- Check safety devices during close: Command the door to close and watch the photocell LEDs and safety edge. If the beam is blocked or the edge is compressed, the board will inhibit closing.
- Verify logic mode: In the Nice programming menu, confirm the operating logic (step‑by‑step, automatic closing, condominium, etc.) is appropriate for a residential door. Some logics restrict closing from certain commands.
- Inspect close limit switch: If the board thinks the door is already closed, it may ignore close commands. Check the close limit switch or encoder reference and re‑set limits if necessary.
- Test with photocells bypassed (temporarily for diagnosis only): If allowed by local regulations, temporarily bridge the photocell terminals at the board to see if the door will close. If it does, the photocells or their wiring are at fault. Restore proper safety devices immediately after testing.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Nice photocell circuit or limit switch