Skylink
Closing Load Imbalance / Track or Hinge Binding
Door opens normally but struggles or stalls when closing
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Bent vertical track, Loose or misaligned hinges, Damaged rollers, Door out of square
How to Fix / Troubleshooting
Safety first: Support the door securely when working on hinges or tracks.
- Inspect vertical tracks: Look for bends or inward bowing that could pinch rollers. Gently straighten and realign as needed.
- Check hinges: Tighten loose hinge screws and replace cracked hinges. Ensure hinge knuckles are not rubbing against the track.
- Replace bad rollers: Swap out any rollers that do not spin freely with compatible garage door rollers.
- Re‑test: After mechanical corrections, test door balance by hand, then reconnect the Skylink opener and test closing.
Advertisements
Repair Difficulty
Medium
3/5