E17
Skylink
Safety Sensor Override / Constant‑Pressure Close Mode
Door opens but will not close from remote; must hold wall button continuously; E17 or flashing sensor indicator
Advertisements
Possible Causes
Safety sensors not functioning, Sensor wires reversed, One sensor LED off, Control board in constant‑pressure mode due to sensor fault
How to Fix / Troubleshooting
Safety first: Never bypass or tape down the wall button to force the door closed. Fix the safety system instead.
- Check sensor LEDs: Verify both Skylink safety sensors have solid LEDs when the door is open. If one is off or blinking, realign or replace sensors.
- Verify wiring polarity: At the opener, ensure the sensor wires are connected to the correct terminals and polarity as specified by Skylink. Reverse them if wired incorrectly.
- Test close from remote: Once sensors are aligned and LEDs are solid, test closing from the remote. The requirement to hold the wall button should disappear.
- Replace sensors: If LEDs will not light despite correct wiring and alignment, replace the Skylink safety sensor pair.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Skylink Safety Sensor Pair
Check Price on Amazon