E8
Skylink Safety Sensor Wiring Short / Open Circuit

Opener lights flash repeatedly and unit will not run; E8 indicated

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Shorted sensor wires, Broken wire between sensor and opener, Incorrect wiring at terminals, Defective sensor harness

How to Fix / Troubleshooting

Safety first: Unplug the opener before manipulating sensor wiring. Do not twist wires together while power is applied.

  • Visual inspection: Follow the sensor wires from each Skylink safety sensor to the opener. Look for crushed insulation, staples through the wire, or splices that have come apart.
  • Terminal check: At the opener, remove both sensor wires from the sensor terminals. Inspect for corrosion or loose screws. Trim and re‑strip the wire ends if necessary, then reconnect firmly.
  • Continuity test (optional): Using a multimeter set to continuity, test each conductor from the opener end to the sensor end. Replace the cable if open or shorted.
  • Swap sensors: If wiring is good but E8 persists, replace the Skylink safety sensor pair. Ensure correct polarity when reconnecting.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Skylink Safety Sensor Wiring Harness
Check Price on Amazon

We may earn a commission from links on this page.