Sommer Partial Safety Lockout via Sensors

Door opens normally but will not close from remote or keypad; only closes from wall button.

Advertisements

Possible Causes

Photo eyes misaligned only in closing direction, Sensor bracket loose and vibrating, One sensor LED intermittent

How to Fix / Troubleshooting

Safety: Do not operate the door automatically until sensors are reliable.

  • 1. Observe sensors during close: Watch the LEDs while commanding a close. If one flickers, tighten the bracket and realign.
  • 2. Replace weak sensor: If a sensor LED is dim or intermittent despite good wiring, replace the sensor pair.
  • 3. Secure wiring: Ensure sensor wires are not being tugged or moved when the door operates.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Sommer Photo Eye Safety Sensor Kit
Check Price on Amazon