E12
Sommer Direction Relay / Output Stage Fault

Display shows E12; opener may run only in one direction or not at all.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed relay on control board, Shorted motor winding in carriage, Overcurrent event damaging output transistors

How to Fix / Troubleshooting

Safety: Disconnect power before opening the operator housing.

  • 1. Test both directions: With the door disconnected, command the opener to open and close. Note if one direction fails consistently.
  • 2. Listen for relay click: When commanding movement, listen at the opener for relay clicks. No click in one direction suggests a board fault.
  • 3. Inspect board for damage: Look for burn marks near the motor output terminals or relays. If present, the board must be replaced.
  • 4. Check motor carriage resistance: With power off and carriage disconnected, measure motor winding resistance (per Sommer specs if available). A shorted motor can cause E12 and will require carriage replacement.
  • 5. Replace failed component: Replace the control board if the output stage is damaged; replace the motor carriage if the motor windings are shorted.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Sommer Control Board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements