Sommer Courtesy Light Circuit Fault

Opener light does not turn on during operation or stays on constantly.

Advertisements

Possible Causes

Burned‑out bulb, Wrong bulb type causing overload, Stuck light relay on control board, Light timer setting misconfigured

How to Fix / Troubleshooting

Safety: Turn off power before changing bulbs.

  • 1. Replace bulb: Install a new bulb of the correct wattage and type recommended by Sommer (often LED or low‑wattage incandescent).
  • 2. Check socket: Inspect the light socket for corrosion or heat damage. Clean contacts or replace socket if necessary.
  • 3. Verify timer setting: Some Sommer models allow adjustment of light‑on time. Reset to factory default per manual.
  • 4. If light stuck on/off: The light relay on the control board may be welded or open. Replace the control board if the light cannot be controlled by settings.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Sommer Control Board
Check Price on Amazon

We may earn a commission from links on this page.