American Standard Switch or Control Stuck Closed

Disposal turns on by itself or continues to run after the wall switch is turned off.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed wall switch contacts welded closed, Miswired constant hot to disposal, Faulty smart control relay stuck on, Shorted switch loop

How to Fix / Troubleshooting

Safety first: Immediately turn OFF the breaker feeding the disposal. Do not leave a self-running disposal energized.

  • Verify switch wiring: With breaker OFF, remove the wall switch cover and confirm the disposal is wired through the switch, not directly to constant hot.
  • Replace switch: If wiring is correct but the disposal runs whenever the breaker is ON, replace the wall switch with a new one rated for motor loads.
  • Check smart control: If using an American Standard smart or remote control, disconnect or bypass the control module to see if the problem stops. Replace the module if its relay is stuck.
  • Test operation: Restore power and confirm the disposal only runs when the switch is ON.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Wall Switch or Smart Control Module
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements