Astracast Overload Protector Tripped

Astracast disposal will not turn on; no sound, but the red reset button on the bottom has popped out.

Advertisements

Possible Causes

Temporary motor overload from jammed food, Running disposal without water, Extended continuous operation, Slight motor overheating

How to Fix / Troubleshooting

Safety First: Turn OFF the wall switch and ensure no one can accidentally turn it on while you work.

  • Step 1 – Clear chamber: Remove visible debris from the grinding chamber using tongs or pliers. Rotate the grinding plate manually with a wooden tool to ensure it moves freely.
  • Step 2 – Allow cooling: Wait 5–10 minutes for the motor to cool down.
  • Step 3 – Press reset: Firmly press the red reset button on the bottom of the Astracast unit until it clicks.
  • Step 4 – Test: Turn on cold water, then switch the disposal ON briefly. If it runs normally, resume normal use but avoid overloading.
  • Step 5 – Monitor: If the reset trips repeatedly, further diagnosis of motor or bearing issues is required.

Warning: Never reset repeatedly without addressing the cause; this can damage the motor.

Advertisements

Repair Difficulty

Very Easy 1/5
Advertisements