E10
Astracast
Imbalance or Mounting Misalignment
Astracast disposal vibrates excessively and causes the sink and countertop to shake during operation.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Bent Astracast grinding plate, Missing or stuck impeller lug, Loose mounting ring or support bracket, Uneven or warped sink flange causing off-center rotation
How to Fix / Troubleshooting
Safety First: Turn OFF power at the breaker before making adjustments under the sink.
- Step 1 – Check for foreign objects: Inspect the grinding chamber and remove any debris that could cause imbalance.
- Step 2 – Inspect impeller lugs: Ensure both (or all) impeller lugs swing freely on the grinding plate. Free any stuck lugs using a wooden tool.
- Step 3 – Verify mounting tightness: From under the sink, check that the Astracast mounting ring is fully locked and evenly tightened. Tighten mounting screws or tabs as specified in the installation manual.
- Step 4 – Check sink flange alignment: Look up into the sink opening to confirm the grinding plate is centered. If the flange is visibly off-center, the sink flange may need to be reinstalled.
- Step 5 – Test with water: Restore power, run cold water, and test. If severe vibration persists, the grinding plate may be bent and the unit should be replaced.
Warning: Excessive vibration can loosen plumbing joints and cause leaks; address promptly.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Astracast mounting ring assembly
Check Price on Amazon