E16
Electrolux
Faulty Internal Overload / Thermal Protector
Disposal will not run unless the reset button is pressed each time before use.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Weak or damaged overload protector, Overheating due to partial jam, High internal resistance in motor windings
How to Fix / Troubleshooting
Safety First: Turn OFF power at the breaker before working on the unit.
- Step 1 – Check for overheating causes: Inspect the chamber for obstructions and ensure the impeller plate spins freely. Clear any jams.
- Step 2 – Adjust usage: Avoid long continuous runs and heavy loads that can overheat the motor.
- Step 3 – Inspect ventilation: Ensure there is adequate airflow around the disposal under the sink and that insulation or stored items are not blocking it.
- Step 4 – Evaluate overload device: If the unit is cool to the touch but still requires reset before every use, the internal overload protector is likely failing.
- Because the overload is integrated into the motor assembly on most Electrolux models, replacement of the entire disposal is typically required.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Complete Disposal Unit
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements