Electrolux Air Switch / Pneumatic Control Failure

Disposal will not operate when the air switch button is pressed (for models using an air switch), but unit runs if wired directly.

Advertisements

Possible Causes

Cracked or disconnected air tubing, Faulty air switch button, Failed air switch control module, Water in air line

How to Fix / Troubleshooting

Safety First: Turn OFF power at the breaker before working on the air switch system.

  • Step 1 – Inspect air tubing: Check the clear or opaque tubing between the countertop button and the control module for kinks, cracks, or disconnections. Reattach or replace as needed.
  • Step 2 – Check for moisture: If water is visible in the tubing, remove it and blow out moisture or replace the tubing.
  • Step 3 – Test button: Press the air switch button while listening at the control module. If no click is heard, the button or tubing is faulty.
  • Step 4 – Replace air switch kit: If tubing and button are intact but the module does not energize the disposal, replace the complete Electrolux-compatible air switch kit.