Everbilt Batch Feed Actuator / Magnetic Switch Not Engaging

Batch-feed Everbilt garbage disposal will not start when stopper is inserted

Advertisements

Possible Causes

Incorrect stopper orientation, Debris preventing stopper from seating, Worn batch-feed lid magnet, Failed internal magnetic switch

How to Fix / Troubleshooting

Safety first: Ensure the unit is plugged into a GFCI outlet and the breaker is ON.

  • Check stopper position: For Everbilt batch-feed models, the stopper must be inserted and turned to the ON position. Align the tabs as shown in the user manual.
  • Clean stopper and opening: Remove the stopper and clean both the stopper and the sink opening to remove food debris that may prevent full engagement.
  • Inspect stopper magnet: If the stopper has a magnet, ensure it is not cracked or missing. Replace the stopper if damaged.
  • Test outlet: Plug in another device to confirm the outlet has power.
  • If still not starting: The internal batch-feed switch or control module may have failed. Replacement of the Everbilt disposal is typically required.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Batch-feed stopper / lid
Check Price on Amazon

We may earn a commission from links on this page.