Everbilt
Restricted Outlet or Low Water Flow
Garbage disposal runs but food remains in chamber and does not clear
Advertisements
Possible Causes
Partially clogged discharge elbow, Insufficient water flow from faucet, Baffle blocking outlet, Grease buildup in drain line
How to Fix / Troubleshooting
Safety first: Turn OFF the disposal before inspecting.
- Increase water flow: Run cold water at full volume while operating the Everbilt disposal for 30–60 seconds.
- Check baffle: Ensure the splash guard is not deformed and blocking the outlet. Replace if necessary.
- Clean discharge elbow and trap: Remove and clean the elbow and P-trap to clear any buildup.
- Avoid fibrous foods: Do not put large amounts of celery, corn husks, or similar items that can wrap around impellers.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Discharge elbow and sink P-trap
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements