E30
Evergrind
Backfed or Miswired Switch Circuit
Disposal produces a noticeable electrical buzzing or humming even when the switch is off
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Shared neutral causing Evergrind backfeed, Miswired Evergrind wall switch line/load, Neutral and ground bonded in Evergrind junction box, Induced voltage from adjacent wiring
How to Fix / Troubleshooting
Safety first: Turn OFF the breaker and verify power is off before opening any boxes.
- Inspect switch wiring: Confirm that the Evergrind hot feed and load are correctly placed on the switch terminals and that no neutral is connected to the switch.
- Check junction box: Ensure neutrals are properly tied together and not bonded to ground in the Evergrind junction box.
- Separate circuits: If the Evergrind shares a cable with another circuit, have an electrician correct any multi-wire branch circuit issues.
- Test: Restore power and verify that no buzzing occurs when the switch is off.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Evergrind wall switch
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements