InSinkErator Switch Contact Arcing / Underrated Control

Disposal causes a buzzing or humming noise from the wall switch or air switch control box

Advertisements

Possible Causes

Worn wall switch contacts, Loose wire at switch terminals, Air switch control box relay failing, Using non-rated switch for motor load

How to Fix / Troubleshooting

Safety first: Turn off the breaker before opening any switch boxes.

  • Inspect wall switch: Remove the cover and check for discoloration, melting, or loose wires. Replace the switch with a heavy-duty, motor-rated switch if any damage is found.
  • Check air switch box: If the buzzing comes from the InSinkErator air switch control box, unplug it and replace the box.
  • Tighten connections: Ensure all terminal screws are snug and wires are properly wrapped.
  • Test: Restore power and verify quiet operation.