E11
McAlpine Wall Switch / Control Circuit Fault

Disposal will not start from the wall switch, but starts if the built-in air switch (if fitted) is used; LED flashes once-long, once-short.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty wall switch contacts, Loose live conductor at McAlpine terminal block, Damaged control cable, Miswired switch loop

How to Fix / Troubleshooting

Safety first: Isolate power at the breaker before opening any switch or junction box.

  • Test the wall switch: Replace the wall switch with a known-good unit or test continuity with a multimeter (qualified persons only).
  • Inspect wiring at disposal: Remove the lower cover on the McAlpine unit and check that live and neutral conductors are firmly secured in the terminal block.
  • Check for damaged cable: Follow the cable from the switch to the disposal, looking for pinched or cut insulation. Replace the cable if damaged.
  • Confirm correct wiring: Ensure the switch is wired in the live conductor only, not neutral, according to local regulations.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Wall Switch / Control Cable
Check Price on Amazon