Miele
Thermal or Overload Trip Under Light Load
Disposal shuts off by itself after a few seconds of operation without any visible jam.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Weak overload protector, Overheating due to failing motor, Faulty control board sensing overload, Restricted ventilation around unit
How to Fix / Troubleshooting
Safety first: Turn off power at the breaker before touching the unit.
- Check for hidden jams: Confirm the rotor spins freely by hand using the bottom hex socket or jam wrench.
- Ventilation: Remove stored items around the disposal to improve airflow and reduce heat buildup.
- Cooling time: Allow the unit to cool for 30 minutes and then test again with only water running.
- Persistent shutdown: If the unit continues to trip quickly, the overload protector or motor windings may be failing and should be evaluated by a technician.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Motor Overload Protector
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements