E14
Rangemaster
Stuck Relay / Welded Contacts
Garbage disposal runs continuously and will not turn off with the switch or air button.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Welded contacts in air switch module, stuck relay on Rangemaster control PCB, incorrectly wired permanent live feed, faulty wall switch stuck closed
How to Fix / Troubleshooting
Safety first: Immediately switch off power at the breaker or unplug the unit. Do not leave a continuously running disposal powered.
- Check wall switch: If a wall switch controls the unit, replace it if it feels loose or does not click properly.
- Inspect air switch module: For air-switch models, disconnect the air switch module from the mains. If the disposal stops, the module contacts are likely welded closed and the module should be replaced.
- Verify wiring: With power off, confirm that the disposal is wired through a switched live, not directly to permanent live. Correct any miswiring according to Rangemaster wiring diagrams.
- Control PCB fault: On models with electronic control, a stuck relay may require replacement of the control module or the entire unit.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Air switch module or control PCB