Teka Faulty Wall Switch or Switch Wiring

Disposal does not respond to the wall switch, but works when directly powered (tested by a technician).

Advertisements

Possible Causes

Worn switch contacts, Loose terminal screws, Broken conductor in cable, Incorrectly wired live/neutral

How to Fix / Troubleshooting

Safety first: Turn OFF power at the breaker before removing the switch cover.

  • Step 1 – Inspect switch: Remove the wall switch plate and check for loose wires or signs of burning.
  • Step 2 – Tighten connections: Secure all terminal screws and ensure the live feed and switched live are correctly placed.
  • Step 3 – Replace switch: If the switch feels loose, does not click positively, or shows discoloration, replace it with a suitable rated switch.
  • Step 4 – Test operation: Restore power and test the disposal from the new switch.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Wall Switch
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements