COL
AquaRest Spas Cool-Down Mode / Temperature Protection

Display shows COL or COOL and heater does not run; spa may be in a protection mode after an overheat or power event.

Advertisements

Possible Causes

Recent overheat event triggering cool-down, Sensor reading out-of-range low, Control logic lockout after power surge, Misconfigured temperature setpoint or mode

How to Fix / Troubleshooting

Safety: Ensure water temperature is safe before entering the spa.

  • Step 1 – Verify water temperature: Use an external thermometer to confirm actual water temperature. If water is normal but COL persists, it may be a logic or sensor issue.
  • Step 2 – Allow cool-down: Remove the cover and run the jets to help equalize water temperature. Some AquaRest control packs require a cool-down period before reheating.
  • Step 3 – Check mode and setpoint: On the topside control, verify the spa is not in an economy or sleep mode that delays heating. Confirm the set temperature is above current water temperature.
  • Step 4 – Power reset: Turn off the GFCI breaker for 5 minutes, then restore power to clear any temporary logic lockout.

If COL remains with normal water temperature and correct settings, the temperature sensor or control board may need diagnosis.

Advertisements

Repair Difficulty

Easy 2/5